You are here

Own Products

Apart from customer-specific solutions, MTSA Technopower also markets its own line of products for high power labs. Our product line encompasses equipment for short-circuit testing.

 

Following the acquisition of KEMA Techniek in 2003, MTSA Technopower became a supplier of equipment that enables controlled high voltage or current injection. This involves equipment for both the direct and the synthetic test circuit.

 

For further details about our products, please click on the pictures below to open the corresponding product leaflet or contact MTSA Technopower directly.

Productoverzicht Own Products

Product Omschrijving Brochure
Make Switch 1210

MTSA Make Switch 1210:

Rated voltage: 17,5 kV

Making current (symmetric): 100 kA

Closing time* < 8 ms

Precision of make-time: < 0.1 ms

Make Switch 1397

MTSA Make Switch 1397:

Rated voltage: 40,5 kV

Making current (symmetric): 80 kA

Closing time* < 8 ms

Precision of make-time: < 0.1 ms 

Master Break Switch

MTSA Master Break Switch

Rated opening time: <7 ms

Deviation in breaking time: <0,2 ms

Rated voltage: 15.4 kV at 50 Hz & 160 kA

Max. breaking test current: 165 kA

Injection Timer

MTSA Injection Timer

Injection Timer is used in synthetic test circuit

Injection Timer predicts when AC current goes through zero

Injection Timer emits ignition commands to main gap

Injection Timer emits signals to control multi loop devices

Test System For Injection Timer

MTSA Test System For Injection Timer

For checking condition of Injection Timer

Simulates current forms which appear during a short circuit testr

Synthetic Make Switch

Synthetic Make Switch

Rated voltage: 250kV

Rated current: 80 kAeff/5 ms

Main Gap

MTSA Main Gap

Maximum voltage: 600 kV

Two High Energy Gap Firing Units

Timing via Injection Timer

For higher voltages: multiple Gaps in series

High Energy Gap Firing Unit

MTSA High Energy Gap Firing Unit

Power supply: Compressed air - 6 bar

Control unit: via fiber-optic high level input (>30 mWatt)

Ignition pulse maximum voltage: 25 kVolt

Elec. energy of 1st ignition pulse: approx. 0.25 Joule/25 kVolt

Elec. energy of 2nd ignition pulse: approx. 200 Joule/850 Volt

Response time: < 5 micro seconds

Re-Ignition Stack

MTSA Re-Ignition Stack

Input:

  • Light: 860 nm
  • Minimum optical capacity: 50 mW
  • SMA-connector. Rise time < 0.5 μs

Delay: < 1,5 μs

Timing accuracy < 0,5 μs

Voltage: 10 kV tot 25kV per section

Maximum charge transfer: 0,5 C per injection

Maximum current: 5000 A

Rogowski Measuring Set

Measuring high electric currents:

Sensitivity: from 0.5 kA/V to 50 kA/V

Current range: currents up to a maximum of 1 mega ampere

Frequency range: LF to 0.007 Hz 

 Accuracy: better than 1%

Phase error: better than 20 minutes of an arc at 50 Hz